CBCZW - 3362, BLACK TRAFFIC PAINT, 3362

  • MSDS: CBCZW
  • Manufacturer: PERVO PAINT CO
  • Product Name: 3362, BLACK TRAFFIC PAINT, 3362
  • National Stock Number: 8010-00N065621
Product Identification

Product ID:3362, BLACK TRAFFIC PAINT, 3362
MSDS Date:01/22/1993
FSC:8010
NIIN:00N065621
MSDS Number: CBCZW

Responsible Party
PERVO PAINT CO
6624 STANFORD AVE
LOS ANGELES, CA 90001
US

Emergency Phone: 800-424-9300(CHEMTREC)

Info Phone: 213-758-1147

Cage: 86483

Contractor
PERVO PAINT CO
LOS ANGELES, CA 90001 US

Telephone: 213-758-1147

Cage: 86483

Ingredients

VM & P NAPHTHA; (ALIPHATIC HYDROCARBONS)

CAS: 64742-89-8

Fraction By Weight: 6-8%

OSHA PEL 500 PPM (MFR)

ACGIH TLV: 300 PPM (MFR)


METHANOL; (METHYL ALCOHOL) (SARA 313) (CERCLA)

CAS: 67-56-1

RTECS: PC1400000

Fraction By Weight: <0.1%

OSHA PEL 200 PPM, S

ACGIH TLV: 200 PPM;250 STEL, S

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


ETHANE, 1,1,1-TRICHLORO-; (1,1,1-TRICHLOROETHANE) (OZONE

CAS: 71-55-6

RTECS: KJ2975000

Fraction By Weight: 19-22%

OSHA PEL 350 PPM

ACGIH TLV: 350 PPM;450 STEL

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


TOLUENE (SARA 313) (CERCLA)

CAS: 108-88-3

RTECS: XS5250000

Fraction By Weight: 4-6%

OSHA PEL 200 PPM

ACGIH TLV: 50 PPM, S

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


P-DIOXANE; (DIETHYLENE DIOXIDE) (DIETHYLENE ETHER) (SARA

CAS: 123-91-1

RTECS: JG8225000

Fraction By Weight: <0.01%

OSHA PEL 100 PPM, S

ACGIH TLV: 25 PPM, S

EPA Report Quantity: 100 LBS

DOT Report Quantity: 100 LBS


CARBON BLACK

CAS: 1333-86-4

RTECS: FF5800000

Fraction By Weight: 2+/-0.5%

OSHA PEL 3.5 MG/M3

ACGIH TLV: 3.5 MG/M3


2.08

RTECS: 9999999VO

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE:SKIN:PRLNG/RPTD CONT OF PROD MAY
CAUSE IRRIT. EYE:DIRECT CONT OF PROD CAN CAUSE IRRIT.
INHAL:VAP/MIST CAN CAUSE HDCH, NAUS, IRRIT OF NOSE, THROAT & EYES.
MAY PRDCE CNS DEPRESS. INGEST:POIS IF SW ALLOWED. MAY RSLT IN
VOMIT, ASPIR OF VOMITUS INTO LUNGS CAUSES ASPIR PNEUM. CHRONIC:MAY
CAUSE DMG TO (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:CNS, RESP SYS, EYES & SKIN.
CHLOROCARBON MATLS HAVE PRDCD SENSIT OF MYOCARDIUM TO EPINEPHRINE
IN LAB ANIMALS & COULD HAVE SIMILAR EFTS IN HUMANS. ADRENOMIMETICS
(E.G., EPINEPHRINE) MAY BE CON TRAINDICATED EXCEPT FOR
LIFE-SUSTAININGUSES IN HUMANS ACUTELY/CHRONICALLY EXPOS TO
CHLOROCARBONS . NOTE: (SUPDAT)
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:SKIN:WASH AFFECTED AREAS W/WATER WHILE REMOVING CONTAM CLTHG.
GET IMMED MED ATTN. LAUNDER CONTAM CLTHG BEFORE REUSE. EYES:FLUSH
W/GENEROUS AMTS OF WATER FOR AT LST 15 MINS. GET IMMED MED ATTN.
INGEST: DO NOT INDUCE VOMIT. CALL MD IMMED. NEVER GIVE
FLUIDS/INDUCE VOMIT IF VICTIM IS UNCONSCIOUS/HAVING CONVLS.
INHAL:MOVE TO FRESH AIR. AID IN BRTHG, IF NEC & GET MED ATTN.

Fire Fighting

Flash Point Method:TCC
Flash Point:40.0F,4.4C
Lower Limits:1.3%
Upper Limits:11.5%
Extinguishing Media:FOAM, CARBON DIOXIDE OR DRY CHEMICAL.
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED PRESSURE DEMAND SCBA &
FULL PROTECTIVE EQUIPMENT . BLANKET VAPOR W/EXTINGUISHING MEDIA.
Unusual Fire/Explosion Hazard:THERMAL DECOMP PRODS MAY INCL HCL &
PHOSGENE . FLAMM VAP CAN FORM EXPLO MIXT W/AIR. CORR VAP PRDCD BY
THERMAL DECOMP OF CHLORINATED HYDROCARBONS.

Accidental Release

Spill Release Procedures:SPILLS SHOULD BE CONTAINED, SOLIDIFIED &
PLACED IN A RCRA LICENSED FACILITY. HANDLING EQUIPMENT TO BE
GROUNDED TO PREVENT SPARKING. WEAR NIOSH/MSHA APPROVED RESPIRATORS,
EYE & SKIN PROTECTION.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:NONE SPECIFIED BY MANUFACTURER.
Other Precautions:NO SMOKING IN AREA OF USE. DO NOT USE IN GENERAL
VICINITY OF ARC WELDING, OPEN FLAMES OR HOT SURFACES. HEAT &/OR UV
RADIATION MAY CAUSE THE FORMATION OF HCL &/OR PHOSGENE .

Exposure Controls

Respiratory Protection:NIOSH/MSHA APPROVED ORGANIC VAPOR RESPIRATOR
WHEN VAPORS AREA GENERATED ABOVE THE PERMISSIBLE LIMIT.
Ventilation:LOCAL EXHAUST TO CONTROL TO RECOMMENDED PEL.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS .
Other Protective Equipment:EYE WASH FOUNTAIN & DELUGE SHOWER WHICH MEET
ANSI DESIGN CRITERIA . COVERALLS, APRONS, BOOTS - AS NEC TO
(SUPDAT)
Work Hygienic Practices:SHOWER AFTER HANDLING PRODUCT. CLEAN CLOTHING
SHOULD BE WORN DAILY.
Supplemental Safety and Health
EFTS OF OVEREXP:TOLUENE APPEARS ON THE NAVY LIST OF OCCUP CHEM REPRO
HAZARDS. SEEK CONSULTATION FROM APPROP HLTH PROFESSIONALS
CONCERNING LATEST HAZARD LIST INFO & SAFE HANDLING & EXPOSURE INFO
. OTHER PROT EQUIP:PREVENT SKIN CONTACT.

Chemical Properties

Boiling Pt:B.P. Text:165F,74C
Melt/Freeze Pt:M.P/F.P Text:165F,74C
Vapor Pres:100 @ 20C
Vapor Density:4.5
Spec Gravity:1.6
Evaporation Rate & Reference:3.79 MAX(BUTYL ACETATE=1)
Solubility in Water:NEGLIGIBLE
Appearance and Odor:BLACK VISCOUS LIQUID; IRRITATING ODOR.

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING, REDUCING AGENTS IN CONJUNCTION W/HEAT.
Stability Condition to Avoid:KEEP AWAY FROM HEAT, SPARKS OR DIRECT
SUNLIGHT. AVOID USING THIS PROD W/EQUIP CONTAINING ANY
ALUMINUM/ZINC COMPONENTS.
Hazardous Decomposition Products:OXIDES OF CARBON, HYDROCHLORIC ACID &
VERY SMALL AMOUNTS OF PHOSGENE & CHLORINE.

Disposal

Waste Disposal Methods:SEND WASTE TO LICENSED RECLAIMERS OR INCINERATE
IN A RCRA LICENSED FACILITY. DO NOT DISCHARGE INTO WATERWAYS OR
SEWER SYSTEMS. ANY DISPOSAL PRACTICE MUST BE IN COMPLIANCE
W/FEDERAL, STATE & LOCAL REGU LATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.